Contactor Enclosure

Siemens Lighting Contactor 30 amp 6 pole w enclosure
Siemens Lighting Contactor 30 amp 6 pole w enclosure
Paypal   US $1,450.00
Square D 8903SXO13 Mechanically Held Contactor in NEMA 1 Enclosure NEW
Square D 8903SXO13 Mechanically Held Contactor in NEMA 1 Enclosure NEW
Paypal   US $1,400.00
Allen Bradley PLC 5 15 Starters Contactor w Enclosure
Allen Bradley PLC 5 15 Starters Contactor w Enclosure
Paypal   US $1,200.00
SQUARE D SIZE 6 LIGHTING CONTACTOR W NEMA 1 ENCLOSURE
SQUARE D SIZE 6 LIGHTING CONTACTOR W NEMA 1 ENCLOSURE
Paypal   US $1,200.00
SQUARE D SIZE 4 CONTACTOR 8502SFG2VO2FP51S WITH ENCLOSURE 120 VOLT COIL
SQUARE D SIZE 4 CONTACTOR 8502SFG2VO2FP51S WITH ENCLOSURE 120 VOLT COIL
Paypal   US $799.99
NEW Square D 8903SQG11V02 Lighting Contactor 100A 600V w Enclosure
NEW Square D 8903SQG11V02 Lighting Contactor 100A 600V w Enclosure
Paypal   US $738.99
Powered by phpBay Pro

Contactor Enclosure

Guidelines for Performing Infrared Inspections of Motor Control Centers

The Motor Control Center

The MCC enclosure protects personnel from contact with current carrying devices, and it protects the components from various environmental conditions. It is important that the enclosure is mounted to assure accessibility so that qualified personnel (such as a trained thermographer) can open the panel under load. There are different classes and types of MCCs, but generally speaking, an MCC looks like a row of file cabinets with each cabinet representing an MCC section. The drawers of the file cabinet represent the plug-in units that contain the motor control components. Three phase power is distributed within the MCC by bus bars, large metal current carrying bars. The horizontal bus provides three-phase power distribution from the main power supply. Vertical bus in each section is connected from it to individual MCCs. Bracing and isolation barriers are provided to protect against fault conditions. The plug-in units of an MCC have power stabs on the back to allow it to be plugged into the vertical power bus bars of the structure.

Beginning Your MCC Infrared Inspection

Before opening the panel or door on a motor controller, prescan the enclosure to assure a safe opening condition. If excessive heat appears on the surface of the door, extra care should be taken when opening it. The thermographer or escort may decide to note the condition as unacceptable and not take a chance on opening it under load. Once the unit is open, begin with both an infrared and a visual inspection to assure no dangerous conditions exist. Be systematic while conducting the infrared inspection. Remember the system must be under load to conduct the inspection. Work from left to right or follow the circuit through carefully, inspecting all of the components. Look for abnormal thermal patterns caused by high-resistance connections, overloads, or load imbalances. In three-phase systems this can be accomplished by comparing phases. Adjust the level and span on the infrared system to optimize the image. Proper adjustment will identify primary and secondary anomalies. The bus stabs and the connections to the main are important inspection points that are often overlooked or misdiagnosed. The incoming connection to the main horizontal bus is usually located behind a cover or panel that is not hinged. These are typically bolted connections and may have parallel feeders. The bus stab connections on the back of the plug-in units are more difficult to inspect. The thermographer does not have direct view of the connection, and the first indication of a problem can be seen on the incoming conductors feeding the breaker or fused disconnect. Remember, even small temperature rises identified at this point could mean serious problems.

Motor Starters and Motor Controllers

The purpose of the motor starter is to protect the motor, personnel, and associated equipment. Over 90% of the motors used are AC induction motors, and motor starters are used to start and stop them. A more generic term would identify this piece of equipment as a motor controller. A controller may include several functions, such as starting, stopping, overcurrent protection, overload protection, reversing, and braking. The motor starter is selected to match the voltage and horsepower of the system. Other factors used to select the starter include: motor speed, torque, full load current (FLC), service factor (SF), and time rating (10 or 20 seconds).

Understanding the thermal patterns of this equipment is critical to a successful inspection. Also correctly identifying the source of the anomaly can make recommendations more valuable.

Motors may be damaged or their life significantly reduced if they operate continuously at a current above full load current. Motors are designed to handle in-rush or locked rotor currents without much temperature increase, providing there is a limited duration and a limited number of starts. Overcurrents up to locked rotor current are generally caused by mechanical overloading of the motor. The National Electric Code (NEC) describes overcurrent protection for this situation as "motor running overcurrent (overload) protection." This can be shortened to overload protection. Overcurrents caused by short circuits or ground faults are dramatically higher than those caused by mechanical overloads or excessive starts. The NEC describes this type of overcurrent protection as "motor branch-circuit short-circuit and ground-fault protection." This can be shortened to overcurrent protection. The four common varieties of motor starters are: across-the-line, the reversing starter, the multispeed starter, and the reduced voltage starter. Motor starters are generally comprised of the same types of components. These include a breaker or fused disconnect, contactor and overloads. There may also be additional components, including control circuitry and a transformer. Understanding the thermal patterns of this equipment is critical to a successful inspection. Also correctly identifying the source of the anomaly can make recommendations more valuable.

Overcurrent Protection

NEC requires overcurrent protection and a means to disconnect the motor and controller from line voltage. Fused disconnects or thermal magnetic circuit breakers are typically used for overcurrent protection and to provide a disconnect for the circuit. A circuit breaker is defined in NEMA standards as a device designed to open and close a circuit by non-automatic means and to open the circuit automatically on a predetermined overcurrent without injury to itself when properly applied within its rating. If we look at a cutaway of a breaker, we can identify potential connection problems. The line side and load side lugs are the most common source of abnormal heating, but many breakers have a second set of bolted connections on the back of the breaker. Heat from this connection can be misdiagnosed as the main lug. There are also internal contacts where current flow is interrupted by exercising the component. These contacts experience arcing each time the breaker is opened. An arc is a discharge of electric current jumping across an air gap between two contacts. Arcs are formed when the contacts of a circuit breaker are opened under a load. Arcing under normal loading is very small compared to an arc formed from a short circuit interruption. Arcing produces additional heat and can damage the contact surfaces. Damaged contacts can cause resistive heating. Thermal patterns from these poor connections appear as diffuse heating on the surface of the breaker. In addition, there are several types of breakers that have internal coils used for circuit protection. These coils have heat associated with them and can appear to be an internal heating problem, when in fact, it is a normal condition.

Fused Disconnects

Fused disconnects are used to provide over-current protection for motor in the same manner as a breaker. Instead of opening contacts, fuses fail opening the circuit. When overcurrent protection is provided by fuses, a disconnect switch is required for manual opening of the circuit. The disconnect switch and fuse block are typically one assembly. The hinge and blade connections on the switch are a typical source of overheating. High resistance from overuse or underuse is usually the cause. Fuse clips are also a weak connection point for some disconnect designs. Different types or manufacturers of fuses of the same amperage may produce different thermal signatures. While different size or amperage fuses will also have a different thermal pattern, fuse bodies may appear warmer than the rest of the circuit due to conductor size.

Contactors

Starters are made from two building blocks, contactors and overload protection. Contactors control the electric current flow to the motor. Their function is to repeatedly establish and interrupt an electrical power circuit. A contactor can stand on its own as a power control device, or as part of a starter. Contactors operate electromechanically and use a small control current to open and close the circuit. The electromechanical components do the work, not the human hand, as is the case with a knife blade switch or a manual controller. The sequence of operation of a contactor is as follows: first, a control current is applied to the coil; next, current flow into the coil creates a magnetic field which magnetizes the E-frame making it an electromagnet; finally, the electromagnet draws the armature towards it, closing the contacts. A contactor has a life expectancy. If the contactor contacts are frequently opened and closed, it will shorten the life of the unit. As the contacts are exercised, an electrical arc is created between the contacts. Arcs produce heat, which can damage the contacts. Contacts eventually become oxidized with a black deposit. This black deposit may actually improve the electrical connection between the contacts by improving the seat, but burn marks, pitting, and corrosion indicate it is time to replace the contacts. The following thermal patterns are associated with contactors. The coil of the contactor is usually the warmest part of the unit. High temperatures may indicate a breakdown of the coil. Line side and load side lug connections may show high resistance heating from poor connections. Heating from burned and pitted contacts may be thermally "visible" on the body of the contactor.

Overload Protection

The ideal motor overload protection is a unit with current sensing capabilities similar to the heating curve of the motor. It would open the motor circuit when full load current is exceeded. Operation of this device would allow the motor to operate with harmless temporary overloads, but open up when an overload lasts too long.

Typical thermal problems in overloads are found in the connections to the contactor, overload relay, or motor.

This protection can be provided by the use of an overload relay. The overload relay limits the amount of current drawn to protect the motor from overheating. It consists of a current sensing unit and a mechanism to open the circuit. An overload relay is renewable and can work for repeated trip and reset cycles. Overloads, however, do not provide short circuit protection. The melting alloy (or eutectic) overload relay consists of a heater coil, a eutectic alloy, and a mechanical mechanism to activate a tripping device when an overload occurs. The relay measures the temperature of the motor by monitoring the amount of current being drawn. This is done indirectly through a heater coil, which under overload conditions, melts a special solder allowing a ratchet wheel to spin free and open the contact. A bimetallic thermal overload uses a U-shaped bimetal strip. In an overload condition heat will cause the bimetal to deflect and open a contact. The solid state overload relay does not generate heat to cause a trip. Instead, it measures current or a change in resistance. The advantage of this method is that the overload relay doesn't waste energy generating heat and doesn't add to the cooling requirements of the panel. Normal heating for an overload may look like a thermal anomaly. Heat generated in the coil or bimetal may look like a connection problem. Typical thermal problems in overloads are found in the connections to the contactor, overload relay, or motor.

Starters

Starters are the combination of a controller, usually a contactor and an overload relay. The above descriptions of the individual components apply to the starter systems. Reduced voltage starters are used in applications that involve large horsepower motors. They are used to reduce the in-rush current and limit the torque, and thus the mechanical stress on the load. The components of this type of starter should be inspected as the motor steps up to speed. A separate low-voltage starter circuit is used to step the motor up to speed. Once at operating speed, these components are de-energized.

Completing Inspections

Remember that primary anomalies are the problems that readily stand out while secondary anomalies may require that primary anomalies be adjusted into saturation to allow for the identification of a secondary anomaly. For example, different fuse types and sizes will cause different thermal signatures as will overload relays that are sized differently within the same circuit. Anomalies like this should be identified and reported. Also note that when evaluating the severity of a problem, temperature is just one variable. All of the parameters involved with the severity of the anomaly should be considered. To improve temperature measurements, avoid low emissive surfaces. Look for cavity radiators or highly emissive insulation on conductors. Measure loads where component sizing, overloading, or load imbalances are observed. Beware of the effects of wind or convection on components. Note ambient temperatures, large thermal gradients, and the source of heating. Safety should be the top consideration.

Conclusion

Knowing the equipment under inspection allows for the correct identification of problems that could be misdiagnosed or overlooked. Analyzing unfamiliar thermal patterns on a component is easier when equipment design is reviewed. More precise repair recommendations can also be made. Locating temperature differences qualitatively or quantitatively is the real benefit of infrared thermography. Knowing where to look for these temperature differences comes from knowledge of the equipment, and knowledge of the equipment will make a better thermographer.

Please visit us at www.electrophysics.com/snellmcab

For more comprehensive White Papers visit our online Knowledge Center. www.electrophysics.com/thermal-imaging

Electrophysics - IR Cameras for Thermography Professionals

373 Route 46, Fairfield, NJ 07004  Phone: 973-882-0211   Fax: 973-882-0997

About the Author

Siemens Lighting Contactor 30 amp 6 pole w enclosure
Siemens Lighting Contactor 30 amp 6 pole w enclosure
Paypal   US $1,450.00
Square D 8903SXO13 Mechanically Held Contactor in NEMA 1 Enclosure NEW
Square D 8903SXO13 Mechanically Held Contactor in NEMA 1 Enclosure NEW
Paypal   US $1,400.00
Allen Bradley PLC 5 15 Starters Contactor w Enclosure
Allen Bradley PLC 5 15 Starters Contactor w Enclosure
Paypal   US $1,200.00
SQUARE D SIZE 6 LIGHTING CONTACTOR W NEMA 1 ENCLOSURE
SQUARE D SIZE 6 LIGHTING CONTACTOR W NEMA 1 ENCLOSURE
Paypal   US $1,200.00
SQUARE D SIZE 4 CONTACTOR 8502SFG2VO2FP51S WITH ENCLOSURE 120 VOLT COIL
SQUARE D SIZE 4 CONTACTOR 8502SFG2VO2FP51S WITH ENCLOSURE 120 VOLT COIL
Paypal   US $799.99
NEW Square D 8903SQG11V02 Lighting Contactor 100A 600V w Enclosure
NEW Square D 8903SQG11V02 Lighting Contactor 100A 600V w Enclosure
Paypal   US $738.99
Square D 8903LXG1200 Contactor in Enclosure
Square D 8903LXG1200 Contactor in Enclosure
Paypal   US $669.99
NEW ALLEN BRADLEY 500L DOB92 100 AMP CONTACTOR IN ENCLOSURE
NEW ALLEN BRADLEY 500L DOB92 100 AMP CONTACTOR IN ENCLOSURE
Paypal   US $599.99
Motor Control Starter Lighting Contactor Control 5 Pole 30A NEMA 1 Enclosure Box
Motor Control Starter Lighting Contactor Control 5 Pole 30A NEMA 1 Enclosure Box
Paypal   US $555.99
Cutler Hammer Enclosure Lighting Contactor ECN3308CAA
Cutler Hammer Enclosure Lighting Contactor ECN3308CAA
Paypal   US $550.00
Square D 8903 SQO 11 Lighting Contactor 100 Amp 3 Pole with NEMA 1 Enclosure
Square D 8903 SQO 11 Lighting Contactor 100 Amp 3 Pole with NEMA 1 Enclosure
Paypal   US $539.99
Allen Bradley Size 0 Motor Starter w Enclosure Disconnect  Contactor
Allen Bradley Size 0 Motor Starter w Enclosure Disconnect Contactor
Paypal   US $500.00
GE 100 AMP LIGHTING CONTACTOR WITH ENCLOSURE NEW
GE 100 AMP LIGHTING CONTACTOR WITH ENCLOSURE NEW
Paypal   US $500.00
SQUARE D 8903SMG12 LIGHTING CONTACTOR ENCLOSURE COMPLETE 30 AMPERES 3 POLE NEW
SQUARE D 8903SMG12 LIGHTING CONTACTOR ENCLOSURE COMPLETE 30 AMPERES 3 POLE NEW
Paypal   US $500.00
NEW Square D lighting contactor 12 pole 20 amps nema 1 enclosure class 8903
NEW Square D lighting contactor 12 pole 20 amps nema 1 enclosure class 8903
Paypal   US $499.00
Square D 8903LXG1200 Contactor with New Rainproof Enclosure
Square D 8903LXG1200 Contactor with New Rainproof Enclosure
Paypal   US $479.00
SQUARE D 8903 SQO11 100 AMP 120V COIL 3 POLE LIGHTING CONTACTOR ENCLOSURE
SQUARE D 8903 SQO11 100 AMP 120V COIL 3 POLE LIGHTING CONTACTOR ENCLOSURE
Paypal   US $450.00
SIEMENS ENCLOSURE LIGHTING CONTACTOR MOTOR ENC1F44T
SIEMENS ENCLOSURE LIGHTING CONTACTOR MOTOR ENC1F44T
Paypal   US $429.62
SQUARE D 8903 LG80VO2 8 POLE LIGHTING CONTACTOR NIB WITH ENCLOSURE
SQUARE D 8903 LG80VO2 8 POLE LIGHTING CONTACTOR NIB WITH ENCLOSURE
Paypal   US $429.00
SQUARE D 8903 LG1000VO2 10 POLE LIGHTING CONTACTOR NIB WITH ENCLOSURE
SQUARE D 8903 LG1000VO2 10 POLE LIGHTING CONTACTOR NIB WITH ENCLOSURE
Paypal   US $429.00
SQUARE D NEMA SIZE SZ 3 8502 SEG2 CONTACTOR  ENCLOSURE
SQUARE D NEMA SIZE SZ 3 8502 SEG2 CONTACTOR ENCLOSURE
Paypal   US $425.00
Electrical Enclosure Box Type 1 with size 2 contactor
Electrical Enclosure Box Type 1 with size 2 contactor
Paypal   US $425.00
ABB 130 Amp Contactor in Nema 12 Enclosure
ABB 130 Amp Contactor in Nema 12 Enclosure
Paypal   US $400.00
GE 463M40NJA10A0 Lighting Contactor Mechanically Held w enclosure NIB
GE 463M40NJA10A0 Lighting Contactor Mechanically Held w enclosure NIB
Paypal   US $400.00
NEW SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 8 POLE 8903LXG80V02
NEW SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 8 POLE 8903LXG80V02
Paypal   US $400.00
SQUARE D 8903LA1200V02 30A SERIES C TYPE 12 ENCLOSURE LIGHTING CONTACTOR NIB
SQUARE D 8903LA1200V02 30A SERIES C TYPE 12 ENCLOSURE LIGHTING CONTACTOR NIB
Paypal   US $399.99
Cutler Hammer ECLO4E1A3A Lighting Contactor 100 Amp 120V 3 Pole Type 1 Enclosure
Cutler Hammer ECLO4E1A3A Lighting Contactor 100 Amp 120V 3 Pole Type 1 Enclosure
Paypal   US $380.00
SQUARE D ENCLOSURE LIGHTING CONTACTOR 8502SBA20V2S SERIES A TYPE 12 NIB
SQUARE D ENCLOSURE LIGHTING CONTACTOR 8502SBA20V2S SERIES A TYPE 12 NIB
Paypal   US $374.99
Square D Lighting Contactor in Enclosure 8903 LX060R6 30 Amp 125 X 75 5814
Square D Lighting Contactor in Enclosure 8903 LX060R6 30 Amp 125 X 75 5814
Paypal   US $358.00
Square D 30 Amp Lighting Contactor 12 3R Enclosure
Square D 30 Amp Lighting Contactor 12 3R Enclosure
Paypal   US $350.00
NIB Square D LIGHTING CONTACTOR 8903SMG11V02 30 AMP 120 V 3 POLE NEMA1 ENCLOSURE
NIB Square D LIGHTING CONTACTOR 8903SMG11V02 30 AMP 120 V 3 POLE NEMA1 ENCLOSURE
Paypal   US $349.99
NEW Square D 8903LXG60 Contactor in Enclosure
NEW Square D 8903LXG60 Contactor in Enclosure
Paypal   US $349.99
Furnas 42FE15AG106GR 75V 2 Pole Open Enclosure Define Purpose Magnetic Contactor
Furnas 42FE15AG106GR 75V 2 Pole Open Enclosure Define Purpose Magnetic Contactor
Paypal   US $339.99
NEW Square D Lighting Contactor in Enclosure 8903 Type XL 20AMP  LC 101
NEW Square D Lighting Contactor in Enclosure 8903 Type XL 20AMP LC 101
Paypal   US $335.00
Cutler Hammer C10EG3 Size 3 Starter ContactorEnclosure
Cutler Hammer C10EG3 Size 3 Starter ContactorEnclosure
Paypal   US $329.99
Square D Lighitng Contactor in Enclosure 8903 LG 80 NIB
Square D Lighitng Contactor in Enclosure 8903 LG 80 NIB
Paypal   US $325.00
594 Stainless Light Contactor 8903 Enclosure NEW
594 Stainless Light Contactor 8903 Enclosure NEW
Paypal   US $325.00
Square D starter contactor size 3 480v coil nema1 enclosure
Square D starter contactor size 3 480v coil nema1 enclosure
Paypal   US $325.00
Cutler Hammer W240M1CFC contactor OL combo 3 pole open enclosure 120V coil
Cutler Hammer W240M1CFC contactor OL combo 3 pole open enclosure 120V coil
Paypal   US $300.00
New Out Of The Box Siemens lighting contactor with enclosure CLM1C04120
New Out Of The Box Siemens lighting contactor with enclosure CLM1C04120
Paypal   US $300.00
ASCO 91782031C LIGHTING CONTACTOR 110 120V COIL IN NEMA 1 ENCLOSURE
ASCO 91782031C LIGHTING CONTACTOR 110 120V COIL IN NEMA 1 ENCLOSURE
Paypal   US $300.00
SIEMENS LIGHTING CONTACTOR W ENCLOSURE CATLEN00B012120A NIB
SIEMENS LIGHTING CONTACTOR W ENCLOSURE CATLEN00B012120A NIB
Paypal   US $299.99
Gould I T E 3 Pole AC Magnetic Contactor 104F w Enclosure
Gould I T E 3 Pole AC Magnetic Contactor 104F w Enclosure
Paypal   US $299.99
Square d size 3 50 amp contactor motor starter w on off button and enclosure
Square d size 3 50 amp contactor motor starter w on off button and enclosure
Paypal   US $299.00
Allen Bradley Size Sz 2 Starter Contactor w Enclosure 702 702CAD92 220v coil NEW
Allen Bradley Size Sz 2 Starter Contactor w Enclosure 702 702CAD92 220v coil NEW
Paypal   US $299.00
Square D Nema 1 8702 SEG 2 Enclosure Contactor
Square D Nema 1 8702 SEG 2 Enclosure Contactor
Paypal   US $299.00
Square D 20A Lighting Contactor in Enclosure type LH 1200
Square D 20A Lighting Contactor in Enclosure type LH 1200
Paypal   US $275.00
565 CLH0F52 200 AMP Siemens Lighting Contactor 3TB52 3 Pole w Enclosure
565 CLH0F52 200 AMP Siemens Lighting Contactor 3TB52 3 Pole w Enclosure
Paypal   US $265.00
SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 10 POLE
SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 10 POLE
Paypal   US $260.00
NOS SQUARE D CONTACTOR WITH ENCLOSURE 8702 SAG4 8702SAG4
NOS SQUARE D CONTACTOR WITH ENCLOSURE 8702 SAG4 8702SAG4
Paypal   US $259.95
Hoffman Enclosure w disconnect and Contactors
Hoffman Enclosure w disconnect and Contactors
Paypal   US $250.00
NEW Square D Lighting Contactor With Enclosure 12 12 6H STR1572
NEW Square D Lighting Contactor With Enclosure 12 12 6H STR1572
Paypal   US $250.00
Square D Size 3 Contactor 120 V Coil NEMA 1 Enclosure
Square D Size 3 Contactor 120 V Coil NEMA 1 Enclosure
Paypal   US $250.00
Square D 8903 Lighting Contactor W Enclosure 100A SW 96
Square D 8903 Lighting Contactor W Enclosure 100A SW 96
Paypal   US $249.99
Square D 100 Amp Lighting Contactor w Enclosure SQ02
Square D 100 Amp Lighting Contactor w Enclosure SQ02
Paypal   US $249.95
NIB SQUARE D LIGHTING CONTACTOR 8903 TYPE LLG 20 20AMP 120V 2P NEMA1 ENCLOSURE
NIB SQUARE D LIGHTING CONTACTOR 8903 TYPE LLG 20 20AMP 120V 2P NEMA1 ENCLOSURE
Paypal   US $229.99
SQUARE D 8502 SDG 1 CONTACTOR W ENCLOSURE New
SQUARE D 8502 SDG 1 CONTACTOR W ENCLOSURE New
Paypal   US $226.96
Square D 8502 EG2 Size 3 Contactor Nema 1 Enclosure Old Style but look $ NIB
Square D 8502 EG2 Size 3 Contactor Nema 1 Enclosure Old Style but look $ NIB
Paypal   US $225.00
Square D starter contactor size 2 480v coil nema1 enclosure
Square D starter contactor size 2 480v coil nema1 enclosure
Paypal   US $225.00
Cutler Hammer ECL03C1U2A TYPE 1 Enclosure CN35DN3 30 amp Lighting Contactor
Cutler Hammer ECL03C1U2A TYPE 1 Enclosure CN35DN3 30 amp Lighting Contactor
Paypal   US $205.00
cutler hammer lighting contactor in nema 1 enclosure 120v coil new nib
cutler hammer lighting contactor in nema 1 enclosure 120v coil new nib
Paypal   US $200.00
ALLEN BRADLEY 500L D0D93 LIGHTING CONTACTOR AND ENCLOSURE
ALLEN BRADLEY 500L D0D93 LIGHTING CONTACTOR AND ENCLOSURE
Paypal   US $200.00
CUTLER HAMMER ECN0501CHA NEMA 1 ENCLOSURE CONTACTOR
CUTLER HAMMER ECN0501CHA NEMA 1 ENCLOSURE CONTACTOR
Paypal   US $200.00
SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 8 POLE
SQUARE D LIGHTING CONTACTOR ENCLOSURE 120V COIL 8 POLE
Paypal   US $200.00
MORRIS MAGNETIC CONTACTOR NIB OPEN ENCLOSURE
MORRIS MAGNETIC CONTACTOR NIB OPEN ENCLOSURE
Paypal   US $199.99
Square D LIGHTING CONTACTOR 8903 Enclosure 100 60 amp S
Square D LIGHTING CONTACTOR 8903 Enclosure 100 60 amp S
Paypal   US $199.99
Allen Bradley Lighting Contactor 100 amp 2 pole 702L DAJ92 with enclosure DOJ92
Allen Bradley Lighting Contactor 100 amp 2 pole 702L DAJ92 with enclosure DOJ92
Paypal   US $199.99
SQUARE D LIGHTING CONTACTOR 3 R ENCLOSURE CAT8903SP02
SQUARE D LIGHTING CONTACTOR 3 R ENCLOSURE CAT8903SP02
Paypal   US $199.99
4420 95 1 GE A 1 Mainline Contactor System enclosure
4420 95 1 GE A 1 Mainline Contactor System enclosure
Paypal   US $199.00
AB Allen Bradley 500L BAD93 CONTACTOR AC LIGHTING 30A 3P NEMA 1TYPE ENCLOSURE
AB Allen Bradley 500L BAD93 CONTACTOR AC LIGHTING 30A 3P NEMA 1TYPE ENCLOSURE
Paypal   US $195.00
Lot of 10 Cooper Manual Contactor Enclosures w Switches AH7810GDB NEW
Lot of 10 Cooper Manual Contactor Enclosures w Switches AH7810GDB NEW
Paypal   US $190.00
NEW Siemens LEN01C003120A Contactor in Enclosure
NEW Siemens LEN01C003120A Contactor in Enclosure
Paypal   US $179.99
Allen Bradley 509 DODD0D Series A Motor Starter Contactor w Enclosure 50 HP
Allen Bradley 509 DODD0D Series A Motor Starter Contactor w Enclosure 50 HP
Paypal   US $176.40
Furnas Contactor 14FP32A In aluminum Enclosure
Furnas Contactor 14FP32A In aluminum Enclosure
Paypal   US $175.00
ET A NEW SQUARE D AC MANUAL STARTER 2510MBG2 NEAMA 1 ENCLOSURE CONTACTOR
ET A NEW SQUARE D AC MANUAL STARTER 2510MBG2 NEAMA 1 ENCLOSURE CONTACTOR
Paypal   US $175.00
WESTINGHOUSE AC LIGHTING CONTACTOR 30 AMPS A202K1CA WITH ENCLOSURE A202S1CA
WESTINGHOUSE AC LIGHTING CONTACTOR 30 AMPS A202K1CA WITH ENCLOSURE A202S1CA
Paypal   US $164.99
SQUARE D 8903LG30 120V COIL CONTACTOR IN ENCLOSURE NIB
SQUARE D 8903LG30 120V COIL CONTACTOR IN ENCLOSURE NIB
Paypal   US $151.10
NEW GE CONTACTOR WITH ENCLOSURE CR360MA313AG
NEW GE CONTACTOR WITH ENCLOSURE CR360MA313AG
Paypal   US $150.00
Allen Bradley Lighting Contactor 60 amp 3 pole 500L CAD93 with enclosure COD93
Allen Bradley Lighting Contactor 60 amp 3 pole 500L CAD93 with enclosure COD93
Paypal   US $150.00
ASCO 917 42031 LIGHTING CONTACTOR 110 120 VOLT IN TYPE 1213 ENCLOSURE
ASCO 917 42031 LIGHTING CONTACTOR 110 120 VOLT IN TYPE 1213 ENCLOSURE
Paypal   US $150.00
ELLIOTT 807 CONTACTOR WITH TANK IN ENCLOSURE NEW
ELLIOTT 807 CONTACTOR WITH TANK IN ENCLOSURE NEW
Paypal   US $150.00
Allen Bradley 110V Enclosure  Contactor 2 Poles NEMA 1 700C11
Allen Bradley 110V Enclosure Contactor 2 Poles NEMA 1 700C11
Paypal   US $150.00
GE type 3R Enclosure  CR4G1WM contactor
GE type 3R Enclosure CR4G1WM contactor
Paypal   US $149.99
GE Motor Contactor CR305R6AEA in Raintight Enclosure
GE Motor Contactor CR305R6AEA in Raintight Enclosure
Paypal   US $149.99
ZENITH CONTROLS ESC10 MAGNETIC CONTACTOR ENCLOSURE NIB
ZENITH CONTROLS ESC10 MAGNETIC CONTACTOR ENCLOSURE NIB
Paypal   US $149.95
Cutler Hammer A10AN0 Contactor and O L Relay in Type 1 Enclosure 115v C799AG15
Cutler Hammer A10AN0 Contactor and O L Relay in Type 1 Enclosure 115v C799AG15
Paypal   US $147.10
Powered by phpBay Pro